AProject
  • Architecture
  • Construction
  • Interior
  • Repair
  • Design
  • Real estate
  • Investments
AProject – all about construction and repair
  • Architecture
  • Construction
  • Interior
  • Repair
  • Design
  • Real estate
  • Investments

Reinforcement for the longitudinal direction of the building

  • July 23, 2018

In the longitudinal direction of the building, a step 6 and 4 m is adopted, and transverse spans should be multiple 1.5 m between the axes. For single -span buildings, spans 9 are recommended; 10.5 and 12 g; These spans for three-span buildings have a total width of 18 g (6+6-1-6); 21 g (6-1-9+6) and 24 F (6+12+6).

For silage structures, greenhouses and greenhouses, until the development of appropriate albums of standard structures from prefabricated reinforced concrete, it is allowed to make individual decisions.

“Instructions for the design of prefabricated reinforced concrete frames and large panels of the floors of multi-storey residential buildings” (U-104-52) of the State Council of the Council of Ministers of the USSR for construction, depending on the nature of the design and reinforcement of parts, the following was established. The brand of concrete of parts without preliminary voltage should not be lower than “200”, and in pre -defeated crossbars – not lower than “300”. In string concrete crossbars, when using an unprocessed wire for a better adhesion to concrete, the concrete brand should not be lower than “400”.

The following reinforcement is recommended:

1) for columns hot -rolled reinforcement of the periodic profile;

2) for crossbars and large panels: a hot -rolled or cold -stranded reinforcement of a periodic profile, a cold wire;

3) for pre-covered crossbars and panels of steel wires of increased strength;

4) for vertical stiffeners – cold wire;

5) for steel parts from shaped rental, which serve to conjure elements of the reinforced concrete frame with each other and with other elements of the building, as well as for lifting loops, steel of stamps is used. 0 and Art. 3. The conjugation must be welded. Bolter mounts are allowed only in mounting joints;

6) To ensure the necessary fire resistance of the structure, steel embedded parts must be covered with a protective layer of concrete with a thickness of at least 2.5 cm.

Share
Tweet
Pin it
Share
Share
You May Also Like
View Post

Choice of home tools: Electric saws

  • January 27, 2025
View Post

Choose good plastic windows

  • January 22, 2025
View Post

What are the sleeping places in the warehouse

  • January 20, 2025
View Post

Classification of slopes: which method to choose

  • January 20, 2025
View Post

Plumbing: a variety of species, which option to buy

  • January 17, 2025
View Post

Options for painting a wooden floor and carry out it

  • January 14, 2025
View Post

Vacuum pump – Building the house –

  • January 9, 2025
View Post

Increase the area of ​​the apartment with design

  • December 31, 2024
Featured Posts
  • How to perform waterproofing the floor yourself
    • June 29, 2018
  • How to solve the problem of fogging windows
    • January 29, 2019
  • “Contraindications” to the use of the Empire style in the design of the interiors of premises for various purposes
    • March 5, 2019
  • How to make a foundation with your own hands from a bottle stone
    • May 4, 2018
  • Sale of gas -free blocks
    • February 1, 2019
Recent Posts
  • The choice of the fittings of plastic windows
    • January 27, 2025
  • Choice of home tools: Electric saws
    • January 27, 2025
  • The choice of diesel generator is the main criteria and principles
    • January 24, 2025
AProject – all about construction and repair
  • © Projectical.net, 2017-2024. All Rights Reserved.

Input your search keywords and press Enter.