Reinforcement for the longitudinal direction of the building

  • July 23, 2018

In the longitudinal direction of the building, a step 6 and 4 m is adopted, and transverse spans should be multiple 1.5 m between the axes. For single -span buildings, spans 9 are recommended; 10.5 and 12 g; These spans for three-span buildings have a total width of 18 g (6+6-1-6); 21 g (6-1-9+6) and 24 F (6+12+6).

For silage structures, greenhouses and greenhouses, until the development of appropriate albums of standard structures from prefabricated reinforced concrete, it is allowed to make individual decisions.

“Instructions for the design of prefabricated reinforced concrete frames and large panels of the floors of multi-storey residential buildings” (U-104-52) of the State Council of the Council of Ministers of the USSR for construction, depending on the nature of the design and reinforcement of parts, the following was established. The brand of concrete of parts without preliminary voltage should not be lower than “200”, and in pre -defeated crossbars – not lower than “300”. In string concrete crossbars, when using an unprocessed wire for a better adhesion to concrete, the concrete brand should not be lower than “400”.

The following reinforcement is recommended:

1) for columns hot -rolled reinforcement of the periodic profile;

2) for crossbars and large panels: a hot -rolled or cold -stranded reinforcement of a periodic profile, a cold wire;

3) for pre-covered crossbars and panels of steel wires of increased strength;

4) for vertical stiffeners – cold wire;

5) for steel parts from shaped rental, which serve to conjure elements of the reinforced concrete frame with each other and with other elements of the building, as well as for lifting loops, steel of stamps is used. 0 and Art. 3. The conjugation must be welded. Bolter mounts are allowed only in mounting joints;

6) To ensure the necessary fire resistance of the structure, steel embedded parts must be covered with a protective layer of concrete with a thickness of at least 2.5 cm.

Share
Tweet
Pin it
Share
Share
You May Also Like
View Post

Interesting ideas and rules for interior design in a classic style

  • June 2, 2025
View Post

How to decorate an interior in a chalet style: ideas and recommendations

  • June 2, 2025
View Post

How to interestingly decorate an interior in a rustic style and recommendations

  • June 2, 2025
View Post

Choice of home tools: Electric saws

  • January 27, 2025
View Post

Choose good plastic windows

  • January 22, 2025
View Post

What are the sleeping places in the warehouse

  • January 20, 2025
View Post

Classification of slopes: which method to choose

  • January 20, 2025
View Post

Plumbing: a variety of species, which option to buy

  • January 17, 2025
Featured Posts
  • Where to start building a dream house: what to take into account
    • May 30, 2018
  • How to make a foundation with your own hands from a bottle stone
    • May 4, 2018
  • Professional wood carving in Moscow
    • February 13, 2019
  • A carrier bath is not only convenient, but also beneficial!
    • December 24, 2018
  • What you need to know about design design
    • May 11, 2018
Recent Posts
  • About the deadlines for apartment renovation: rules and advice
    • June 2, 2025
  • Carrying out apartment renovations under a contract
    • June 2, 2025
  • Handing over repairs: requirements, features and nuances
    • June 2, 2025
AProject – all about construction and repair
  • © Projectical.net, 2017-2024. All Rights Reserved.

Input your search keywords and press Enter.